Accurate fuel consumption measurements are an important part of evaluating gas-powered UAV propulsion systems. Tyto Robotics examines how fuel flow measurements can help engineers assess engine performance under different operating conditions, compare propulsion configurations, and estimate UAV endurance. Read more >>
Fuel flow can be measured by volume or mass, with each approach providing different information about fuel consumption. Several sensor technologies are available for unmanned aerial vehicle (UAV) testing, including turbine, positive displacement, transit-time ultrasonic, and thermal flow sensors. Each uses a different measurement principle and has specific considerations relating to fuel viscosity, flow rates, measurement accuracy, and maintenance.
The article also provides a practical guide to measuring fuel consumption using the Tyto Robotics Flight Stand 60 and Fuel Flow Sensor. The system uses an inline mechanical fuel flow sensor with a measurement range of 20 to 800 mL/min, allowing fuel flow data to be recorded alongside thrust, torque, RPM, temperature, and airspeed during internal combustion engine testing. The guide covers hardware installation, fuel line connections, and software configuration for recording synchronized measurements.
Read the full Tyto Robotics article, How to Measure Drone Fuel Consumption, for a detailed explanation of fuel flow measurement methods and step-by-step instructions for configuring the Flight Stand 60 fuel flow sensor.